HFV-Series Vacuum Pump Oil
  Property  Standard SH 0528  
 
 
Can get three kinds of products, Top-quality, First class and Qualified Product
Different models for different pumps
Meet requirements for vacuum degree and circumtances stated
Good foam property, reduce wear due to overflow and interruption of work fluid
 
  Application  
 
 
HFV-46 can be used to small single stage pump and direct-acting pump of 8 liter
HFV-68,100 can be applied for pumps from 8 liter to 70 liter
 
  Typical data
 
           
Item / Model
Top-Quality
First Class
Testing method
Model
46
68
100
46
68
100
GB/T3141
Kinematic viscosity
(40¡æ)£¬mm2 /s
41.4¡«50.6
61.2¡«74.8
90¡«110
41.4¡«50.6
61.2¡«74.8
90¡«110
GB/T265
Viscosity Index
90
90
90
90
90
90
GB/T254
Flash Poin¡æ
215
225
240
215
225
240
GB/T353
Pour Point¡æ
-9
-9
-9
-9
-9
-9
GB/T353
Demulsibility

(40-40-0)ml,min
54¡æ
10
15
-
30
30
-
GB/T7305
82¡æ
-
-
20
-
-
30
Foam property
24¡æ
100/0
100/0
100/0
-
-
-
93.5¡æ
75/0
75/0
75/0
-
-
-
GB/T12579
24¡æ
100/0
100/0
100/0
-
-
-
Ultimate pressure£¬kPa
Partial pressure
2.7 ¡Á10-5
6.7 ¡Á10-5
GB/T6306.2
Totle pressure
Report
-
Note: Ultimate pressure should be determined with vacuum pump stated in testing method
          Technical data above are values of typical sample,actual parameter will be get by measuring
          products practically
     
  package   4L/Canteen¡¢ 18L/Bucket¡¢ 200L/Barrel   Top
Add:75-1 Pan Yu Road,Shanghai,CN
Zip: 200052
Tel: £¨86-21£©62109273 62121126 62106912 Fax: £¨86-21£©62105356 52397633
Http://www.hfvac.com mail:shxs@hfvac.com